Skip to main content
Layered exploit stack behind this report, with the fault at Chained flaw. Illustration: SecurityXP

CISA flags actively exploited HPE, Danfoss, Mitel MiCollab and Vates Xen Orchestra flaws

· 1 min read · SecurityXP

Key Facts

  • Administrators should apply the security updates provided by Juniper, including versions 7.0.5, 7.1.7 and 7.2.3 for the affected release branches.
  • "Customers are encouraged to upgrade to a fixed release as soon as possible and in the meantime take steps to mitigate this vulnerability." The remaining three security flaws relate to Danfoss AK-SM 800A Series refrigeration controllers that could lead to authentication bypass and arbitrary command execution - - CVE-2023-25914 (CVSS score: 8.8) - A path traversal vulnerability that could allow an attacker to access and read underlying server system files via the XML interface.
  • "Mitel provided a patch available for release 10.3 (10.3.0.18) that addresses these vulnerabilities," the company said in an advisory published November 16, 2026.
  • A fix for the vulnerability is expected to be addressed in an upcoming software version (5.5.x).
  • "Authentication is not required to exploit this vulnerability." Danfoss, which has issued an alert of its own, said the security flaw impacts versions 5.4.0 and earlier.

CISA has flagged HPE, Danfoss, Mitel MiCollab and Vates Xen Orchestra flaws as actively exploited, including a Danfoss path traversal issue that chains to a second vulnerability. The Danfoss issue, CVE-2023-25914, carries a CVSS score of 8.8 and allows an attacker to read underlying server system files through the XML interface. The reported attack chain continues from CVE-2023-25914 to CVE-2023-25915.

Danfoss controller flaws

Danfoss’s alert says versions 5.4.0 and earlier are affected and that authentication is not required to exploit the vulnerability. A fix is expected in upcoming software version 5.5.x. Three related flaws in Danfoss AK-SM 800A Series refrigeration controllers could enable authentication bypass and arbitrary command execution.

Ireland’s National Cyber Security Centre reported in November 2026 that Midnight Blue had identified six previously unknown pre-authentication remote code execution vulnerabilities in Danfoss AK-SM 800A controllers, affecting firmware versions through 5.3.2.

MiCollab and intrusion indicators

Mitel’s CVE-2026-133275 is an unrestricted file upload vulnerability in the Audio, Web and Video Conferencing (AWV) component of MiCollab and carries a CVSS score of 5.3. Mitel issued release 10.3 (10.3.0.18) to address the vulnerabilities in an advisory published November 16, 2026.

Accenture said MiCollab is commonly internet-facing and connected to critical enterprise services, including Active Directory. Accenture’s Apex Labs said an unknown threat actor may have weaponized the flaws as zero-days in a suspected AI-assisted data theft campaign.

Associated intrusion indicators include command-and-control server 204.76.203[.]204, hostname 204.76-203-204.sslip[.]io and address 204.76.203[.]216. The indicators also identify 204.76.203[.]204/bkup/ for data exfiltration and 204.76.203[.]204/bkdl/ for tool downloads.

Tags: CVE-2023-25914 CVE-2023-25915 CVE-2025-41450 CVE-2026-103406 CVE-2026-133275 CVE-2026-133303 CVE-2026-133311 CVE-2026-133323